CATEGORIES
FDF71VNPVD1

Wide and Powerful Air Flow

Easy Transportation and Installation Workability

ModelIndoor FDF71VD1
Outdoor FDC71VNP
Power SourcePh/V/Hz1 / 220-240 / 50
Nominal Cooling CapacityMin~Max kW7.1 ( 1.4 ~ 7.1 )
Nominal Heating CapacityMin~Max kW7.1 ( 1.0 ~ 7.1 )
Power ConsumptionCooling/Heating kW2.67 / 2.04
COPCooling/Heating 2.66 / 3.48
Inrush CurrentA5
Max. CurrentA14.5
Sound Power LevelIndoor (Cooling/Heating) dB(A)61 / 61
Outdoor (Cooling/Heating) dB(A)67 / 67
Sound Pressure Level (Lo – Hi)Indoor (Cooling/Heating) dB(A)33 - 42 / 33 - 42
Outdoor (Cooling/Heating) dB(A)54 / 54
Air Flow (Hi - Lo)Indoor (Cooling/Heating) m3/min20 - 14 / 20 - 14
Outdoor (Cooling/Heating) m3/min36 / 36
Dimension (H x W x D)Indoor mm1,850 x 600 x 320
Outdoor mm640 x 800(+71) x 290
Net WeightIndoor kg49
Outdoor kg45
Refrigerant Piping SizeLiquid / Gas mm(in)6.35(1/4") / 12.7(1/2")
Max. Piping Lengthm23
Max. Piping Height Differencem20
Outdoor Operating Temperature RangeCooling °CDB -15~46
Heating °CDB -15~20