Draft Prevention Panel (Option)
Motion Sensor (Option)
Individual Flap Control System
| Model | Indoor | FDT100VH | |
| Outdoor | FDC90VNP1 | ||
| Power Source | Ph/V/Hz | 1 / 220-240 / 50 ; 220 / 60 | |
| Nominal Cooling Capacity | Min~Max | kW | 9.0 ( 1.9 ~ 9.0 ) |
| Nominal Heating Capacity | Min~Max | kW | 9.0 ( 1.5 ~ 9.0 ) |
| Power Consumption | Cooling/Heating | kW | 2.67 / 2.19 |
| COP | Cooling/Heating | 3.37 / 4.11 | |
| Inrush Current | A | 5 | |
| Max. Current | A | 18 | |
| Sound Power Level | Indoor (Cooling/Heating) | dB(A) | 62 / 62 |
| Outdoor (Cooling/Heating) | dB(A) | 69 / 69 | |
| Sound Pressure Level (Lo – Hi) | Indoor (Cooling/Heating) | dB(A) | 30 - 47 / 29 -47 |
| Outdoor (Cooling/Heating) | dB(A) | 57 / 55 | |
| Air Flow (Hi - Lo) | Indoor (Cooling/Heating) | m3/min | 37 - 17 / 37 - 17 |
| Outdoor (Cooling/Heating) | m3/min | 63 / 49.5 | |
| Dimension (H x W x D) | Indoor | mm | Unit: 298 x 840 x 840 Panel: 35 x 950 x 950 |
| Outdoor | mm | 750 x 880(+88) x 340 | |
| Net Weight | Indoor | kg | 30(Unit:25 Standard Panel:5) |
| Outdoor | kg | 57 | |
| Refrigerant Piping Size | Liquid / Gas | mm(in) | 6.35(1/4") / 15.88(5/8") |
| Max. Piping Length | m | 30 | |
| Max. Piping Height Difference | m | 20 | |
| Outdoor Operating Temperature Range | Cooling | °CDB | -15~46 |
| Heating | °CDB | -15~20 | |