CATEGORIES
FDU125VNAVH

ModelIndoor FDU125VH
Outdoor FDC125VNA
Power SourcePh/V/Hz1 / 220-240 / 50
Nominal Cooling CapacityMin~Max kW12.5 ( 5.0 ~ 14.0 )
Nominal Heating CapacityMin~Max kW14.0 ( 4.0 ~ 16.0 )
Power ConsumptionCooling/Heating kW4.36 / 3.69
COPCooling/Heating 2.87 / 3.79
Inrush CurrentA5
Max. CurrentA26
Sound Power LevelIndoor (Cooling/Heating) dB(A)67 / 67
Outdoor (Cooling/Heating) dB(A)71 / 71
Sound Pressure Level (Lo – Hi)Indoor (Cooling/Heating) dB(A)29 - 45 / 29 - 45
Outdoor (Cooling/Heating) dB(A)55 / 57
Air Flow (Hi - Lo)Indoor (Cooling/Heating) m3/min39 - 20 / 39 - 20
Outdoor (Cooling/Heating) m3/min75 / 73
External Static PressurePaStandard:60 Max:200
Dimension (H x W x D)Indoor mm280 x 1,370 x 740
Outdoor mm845 x 970 x 370
Net WeightIndoor kg54
Outdoor kg80
Refrigerant Piping SizeLiquid / Gas mm(in)9.52(3/8") / 15.88(5/8")
Max. Piping Lengthm50
Max. Piping Height Differencem50 (Higher) / 15(Lower)
Outdoor Operating Temperature RangeCooling °CDB -15~50
Heating °CDB -20~20