External Static Pressure (E.S.P) Control
Motion Sensor (Option)
| Model | Indoor | FDUM50VH x 2 | |
| Outdoor | FDC100VNA | ||
| Power Source | Ph/V/Hz | 1 / 220-240 / 50 | |
| Nominal Cooling Capacity | Min~Max | kW | 10.0 ( 4.0 ~ 11.2 ) |
| Nominal Heating Capacity | Min~Max | kW | 11.2 ( 4.0 ~ 12.5 ) |
| Power Consumption | Cooling/Heating | kW | 3.25 / 3.21 |
| COP | Cooling/Heating | 3.08 / 3.49 | |
| Inrush Current | A | 5 | |
| Max. Current | A | 26 | |
| Sound Power Level | Indoor (Cooling/Heating) | dB(A) | 60 / 60 |
| Outdoor (Cooling/Heating) | dB(A) | 70 / 70 | |
| Sound Pressure Level (Lo – Hi) | Indoor (Cooling/Heating) | dB(A) | 26 - 37 / 26 - 37 |
| Outdoor (Cooling/Heating) | dB(A) | 54 / 56 | |
| Air Flow (Hi - Lo) | Indoor (Cooling/Heating) | m3/min | 13 - 8 / 13 - 8 |
| Outdoor (Cooling/Heating) | m3/min | 75 / 73 | |
| External Static Pressure | Pa | Standard:35 Max:100 | |
| Dimension (H x W x D) | Indoor | mm | 280 x 750 x 635 |
| Outdoor | mm | 845 x 970 x 370 | |
| Net Weight | Indoor | kg | 29 |
| Outdoor | kg | 80 | |
| Refrigerant Piping Size | Liquid / Gas | mm(in) | 9.52(3/8") / 15.88(5/8") |
| Max. Piping Length | m | 50 | |
| Max. Piping Height Difference | m | 50 (Higher) / 15(Lower) | |
| Outdoor Operating Temperature Range | Cooling | °CDB | -15~50 |
| Heating | °CDB | -20~20 | |