CATEGORIES
FDUM100VSAPVH

External Static Pressure (E.S.P) Control

Motion Sensor (Option)

ModelIndoor FDUM50VH x 2
Outdoor FDC100VSA
Power SourcePh/V/Hz3 / 380-415 / 50
Nominal Cooling CapacityMin~Max kW10.0 ( 4.0 ~ 11.2 )
Nominal Heating CapacityMin~Max kW11.2 ( 4.0 ~ 12.5 )
Power ConsumptionCooling/Heating kW3.25 / 3.21
COPCooling/Heating 3.08 / 3.49
Inrush CurrentA5
Max. CurrentA17
Sound Power LevelIndoor (Cooling/Heating) dB(A)60 / 60
Outdoor (Cooling/Heating) dB(A)70 / 70
Sound Pressure Level (Lo – Hi)Indoor (Cooling/Heating) dB(A)26 - 37 / 26 - 37
Outdoor (Cooling/Heating) dB(A)54 / 56
Air Flow (Hi - Lo)Indoor (Cooling/Heating) m3/min13 - 8 / 13 - 8
Outdoor (Cooling/Heating) m3/min75 / 73
External Static PressurePaStandard:35 Max:100
Dimension (H x W x D)Indoor mm280 x 750 x 635
Outdoor mm845 x 970 x 370
Net WeightIndoor kg29
Outdoor kg82
Refrigerant Piping SizeLiquid / Gas mm(in)9.52(3/8") / 15.88(5/8")
Max. Piping Lengthm50
Max. Piping Height Differencem50 (Higher) / 15(Lower)
Outdoor Operating Temperature RangeCooling °CDB -15~50
Heating °CDB -20~20