External Static Pressure (E.S.P) Control
Motion Sensor (Option)
Model | Indoor | FDUM71VH x 3 | |
Outdoor | FDC200VSA | ||
Power Source | Ph/V/Hz | 3 / 380-415 / 50 | |
Nominal Cooling Capacity | Min~Max | kW | 19.0 ( 5.2 ~ 22.4 ) |
Nominal Heating Capacity | Min~Max | kW | 22.4 ( 3.3 ~ 25.0 ) |
Power Consumption | Cooling/Heating | kW | 6.46 / 6.15 |
COP | Cooling/Heating | 2.94 / 3.64 | |
Inrush Current | A | 5 | |
Max. Current | A | 22 | |
Sound Power Level | Indoor (Cooling/Heating) | dB(A) | 65 / 65 |
Outdoor (Cooling/Heating) | dB(A) | 72 / 74 | |
Sound Pressure Level (Lo – Hi) | Indoor (Cooling/Heating) | dB(A) | 25 - 38 / 25 - 38 |
Outdoor (Cooling/Heating) | dB(A) | 58 / 59 | |
Air Flow (Hi - Lo) | Indoor (Cooling/Heating) | m3/min | 24 - 10 / 24 - 10 |
Outdoor (Cooling/Heating) | m3/min | 135 / 135 | |
External Static Pressure | Pa | Standard:35 Max:100 | |
Dimension (H x W x D) | Indoor | mm | 280 x 950 x 635 |
Outdoor | mm | 1,300 x 970 x 370 | |
Net Weight | Indoor | kg | 34 |
Outdoor | kg | 115 | |
Refrigerant Piping Size | Liquid / Gas | mm(in) | 9.52(3/8") / 22.22(7/8") |
Max. Piping Length | m | 70 | |
Max. Piping Height Difference | m | 30 (Higher) / 15(Lower) | |
Outdoor Operating Temperature Range | Cooling | °CDB | -15~50 |
Heating | °CDB | -15~20 |